Instrument Summary IP-4
Overall Summary
The instrument was applied 2 times to N= 937 students. In aggregate, the overall Cronbach's alpha = 0.69
2PL IRT analysis produced model fit with RMSEA = 0 SRMSR = 0.005 CFI = 1 and TLI = 1.006
Item Properties
| ID | Alpha.Dropped | Difficulty.CTT | Discrimination.UL.CTT | Item.Total.Correlation | Difficulty.IRT | Discrimination.IRT |
|---|---|---|---|---|---|---|
| K2-4-V2JS | 0.56 | 0.66 | 0.9 | 0.58 | -0.47 | 3.62 |
| K2-5-V2EC | 0.6 | 0.66 | 0.85 | 0.53 | -0.49 | 2.41 |
| K2-27-V2JS | 0.61 | 0.62 | 0.88 | 0.51 | -0.41 | 2.15 |
| K2-36-V1JS | 0.73 | 0.52 | 0.82 | 0.31 | -0.1 | 0.89 |
For item-total correlation
- Below 0.19 / Negative: Poor discrimination or flawed items. The question fails to separate high and low performers, measures the opposite construct, or contains a faulty answer key.
- 0.20 to 0.39: Fair to good discrimination. The item is acceptable for exploratory scales or basic assessments.
- 0.40 and above: Very good or excellent discrimination. The item strongly aligns with the overall latent construct or test score.
Academic Citations
- For discrimination thresholds (0.19/0.20/0.40): Ebel, R. L., & Frisbie, D. A. (1991). Essentials of Educational Measurement (5th ed.). Prentice-Hall. AI generated. Needs to be checked. Note: This is the foundational text establishing the standard grid for item discrimination efficiency.
Difficult and Discrimination
Test and Item Information
IRT Model Fit
| item | S_X2 | df.S_X2 | RMSEA.S_X2 | p.S_X2 |
|---|---|---|---|---|
| K2.4.V2JSs | 0.28 | 1 | 0 | 0.6 |
| K2.5.V2ECs | 1.72 | 1 | 0.03 | 0.19 |
| K2.27.V2JSs | 0.15 | 1 | 0 | 0.7 |
| K2.36.V1JSs | 0.23 | 1 | 0 | 0.63 |
Item-fit statistics
Item fit was evaluated using the Orlando–Thissen S-X 2 statistic. The columns are interpreted as follows:
- item: Name or identifier of the item being evaluated.
- S_X2: The Orlando–Thissen S-X 2 item-fit statistic. It measures disagreement between observed and model-predicted response frequencies across groups of respondents formed according to their test scores. Larger values relative to the degrees of freedom indicate greater item-level misfit.
- df.S_X2: Degrees of freedom associated with the S-X 2 statistic. The degrees of freedom depend on the number of usable score groups and the number of item parameters estimated.
- RMSEA.S_X2: An item-level RMSEA derived from the S-X 2 statistic. Values closer to zero indicate better fit. Values below approximately 0.05 generally indicate little item-level misfit. These thresholds should be treated as practical guidelines rather than strict hypothesis tests.
- p.S_X2: The p-value for the S-X 2 goodness-of-fit test. A small p-value indicates that the observed response pattern differs significantly from that predicted by the IRT model. A conventional criterion is p < .05 for flagging potential item misfit. Because this test is sensitive to sample size, statistical significance should be considered together with RMSEA.S_X2.
Suggested decision criteria
- Good/acceptable fit: p.S_X2 >= .05 and RMSEA.S_X2 < .05.
- Statistically flagged but small practical misfit: p.S_X2 < .05 but RMSEA.S_X2 < .05. This pattern can occur with large samples.
- Potentially meaningful misfit: p.S_X2 < .05 accompanied by an elevated RMSEA.S_X2 (e.g., >= .05). These items warrant closer substantive and graphical inspection.
Important: The p-value should not generally be used as the sole criterion for removing an item. With large samples, relatively small departures from the model can produce statistically significant S-X 2 tests.
Local Independence Testing
Local Independence Summary
Statistic:
Chen & Thissen’s
X²
/
G²
residual matrix.
Measures shared variance between item pairs after accounting for the latent trait (θ).
Values exceeding 10 indicate significant local dependence. Consider removing an item, creating a testlet, or moving to a multidimensional model.
Item Response Curves
Empirical vs. Theoretical Fit Plot. Solid Line: 2PL Model Expectation | Dots: Observed Proportion Bins (with 95% CI)
Application Summary
| Overall.Instrument | N | Test.Time | Univ | Class | Physics I II | ALGE CALC | alpha | CFI | TLI | RMSEA | SRMSR |
|---|---|---|---|---|---|---|---|---|---|---|---|
| OSU.EM.Pretest.Spr26 | 495 | PreS26 | OSU | 1201 | PHYS II | ALGE | 0.677 | 1 | 1.004 | 0 | 0.016 |
| OSU.EM.Pretest.Spr26 | 442 | PreS26 | OSU | 1251 | PHYS II | CALC | 0.7 | 0.999 | 0.997 | 0.023 | 0.022 |